MC-i4: Creating Frequency Lists

Connecting to an MC-i4 receiver for the purpose of configuring licensed radio frequency lists. 

Log in or sign up for myTopcon to view this page:

MC-i4: Creating Frequency Lists

Connecting to the MC-i4

There are multiple ways to connect to the MC-i4:

  • QTWeb on a GX-60.
  • PC web browser (Programming cables 1001270-01 and 1001269-01 required) .
  • MCXConfig on a GX-55.

Configuring Ethernet Adapter

The process for connecting on a GX-60 and a PC are virtually identical.

  • You must configure the ethernet adapter settings on a GX-60 and PC to connect to the SL-R4 web interface.
  • For the GX-60/Windows XP:
    • Start > Settings > Control Panel > Network Connection > Local Area Connection > Properties > Internet Protocol(TCP/IP) > Properties.
  • For Windows 7 and up:
    • Start > Control Panel > Network and Sharing Center > Change Adapter Settings > Right Click > Properties > Internet Prococol Version 4 (TCP/IPv4) > Properties.
  • IP Address: 192.168.0.10
  • Subnet Mask: 255.255.255.0
  • Default Gateway: 192.168.0.1
  • Preferred DNS server: 192.168.0.1

NOTE: MCXConfig is a standalone application for the GX-55.  Editing the network adapter settings is not required.

Opening Web Interface

  • Use QTWeb on the GX-60 and any web broswer on a PC and enter the following address:
    • 192.168.0.1
  • For a GX-55, open MCXConfig.
  • You should be brought to a login screen. The credentials are as follows:
    • Username: admin
    • Password: admin

Adding UHF Channels

  • Navigate to Sensors > UHF Radio.
  • Click the Channels tab.
  • Input the channel number.
  • Input the channel frequency.
  • Choose the channel spacing.
  • Press Add Row.