- Select the RD-M1 run in the Workspace window.
- Navigate to Fuse > Scan.
Pose scans
- Set Density to 1 to 1.
- Check the box for Maximum range.
- Enter the desired value for maximum scan range.
Maximum range
The maximum scan range limits RD-M1 data to the pavement directly behind the collection vehicle. Using the height of the scanner and the desired width, you can calculate the appropriate value using this equation:
Maximum Range = √[(½ Width)² + (Height)²]
Click Start.